APC Smart-UPS On-Line, 3kVA, Rack/Tower, 120V, 8x 5-20R+1x L5-30R NEMA outlets, SmartSlot, Extended runtime, W/O rail kit [TAA] • Replacement battery (1) is available • 3kVA/2.7kW double-conversion on-line pure sine wave rack/tower UPS • Ideal for servers, storage, voice/data networks, medical labs, and light industrial applications • Rack/Tower convertible (rail kit SRTRK4 or SRTRK3 sold separately) • Delivers clean power with zero transfer time for critical or sensitive devices • Add up to 10 external battery packs (SRT96RMBP) for extended runtime This APC Smart-UPS is designed for IT professionals or network administrators to maintain business uptime and continuity. This 3kVA on-line rack/tower UPS provides pure sine wave power and extended runtime to support critical electronics during power disruptions. It comes with NEMA L5-30P input and 8x NEMA 5-20R and 1x NEMA L5-30R outlets. It has a SmartSlot for optional Network Management Card that enables graceful shutdown of physical servers, virtual machines & HCI Clusters via PowerChute Network Shutdown. The UPS can connect to EcoStruxure IT or third-party centralized management platforms. The UPS has a 3-year warranty, and the built-in lead-acid battery has a 2-year warranty. The UPS is compatible with SRTRK4 (4-post) and SRTRK3 (2-post) rail kits sold separately. |
|
| Main Run time for load 2700W(Min-max: 270-2700 W) 3min 13s Max. Capacity Used 100 % Max. Capacity Used 100% Main input voltage 120 V AC 1 phase Input connection NEMA L5-30P Input frequency 40 - 70 Hz auto-sensing Output voltage 120 V AC 1 phase Rated power in W 2700 W Rated power in VA 3000 VA Output connection 8 NEMA 5-20R 1 NEMA L5-30R Bypass type Internal Bypass (Automatic and Manual) Crest factor 3:01 Harmonic distortion Less than 2% Maximum configurable power in VA 3000 VA Maximum configurable power in W 2700 W UPS topology On-Line Waveform type Sine wave Output frequency 50/60 Hz +/- 3 Hz sync to mains Replacement battery APCRBC152 |
Main Run time for load 2700W(Min-max: 270-2700 W) 3min 13s Max. Capacity Used 100 % Max. Capacity Used 100% Main input voltage 120 V AC 1 phase Input connection NEMA L5-30P Input frequency 40 - 70 Hz auto-sensing Output voltage 120 V AC 1 phase Rated power in W 2700 W Rated power in VA 3000 VA Output connection 8 NEMA 5-20R 1 NEMA L5-30R Bypass type Internal Bypass (Automatic and Manual) Crest factor 3:01 Harmonic distortion Less than 2% Maximum configurable power in VA 3000 VA Maximum configurable power in W 2700 W UPS topology On-Line Waveform type Sine wave Output frequency 50/60 Hz +/- 3 Hz sync to mains Replacement battery APCRBC152 |