APC Power Distribution Unit APDU10350SW NetShelter Rack PDU Advanced Switched 3PH 22.1kW 400V 32A
Status: Available
SKU: 270292
Vendor: APC
MPN: APDU10350SW
UPC: 731304439721
EAN:
APC NetShelter Rack PDU Advanced, Switched, 3PH, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring.
Main Input Voltage
415 V 3 phase
400 V 3 phase
Product or Component Type
PDU
PDU Type
Switched
Main Output Voltage
240 V
Input Connection Type
IEC 60309 30 A 3P+N+PE
Number of rack unit
0U
Cable length
5.91 ft (1.8 m)
communication port protocol
1000BASE-T
10/100BASE-T
Physical
Color
Black
Mounting Location
Side
Mounting preference
No preference
Mounting Mode
Rack-mounted
Mounting position
Vertical