Status: | Available |
SKU: | 203445 |
Vendor: | Tripp Lite |
MPN: | SU750RTXLCD2U |
UPC: | 037332168276 |
EAN: | |
750VA / .75kVA / 675W on-line double-conversion 2U rack / tower UPS 100/110/120/127V 50/60Hz output; High efficiency economy mode option Interactive LCD with 9 selectable screens of UPS and site power data Expandable runtime, Hot-swap batteries, 12.5 in / 31.8 cm depth USB, RS232 & EPO ports, plus support for network card options 2 independently switched load banks NEMA 5-15P input; 6 NEMA 5-15R outlets |
|
OUTPUT Output Volt Amp Capacity (VA) 750 Output kVA Capacity (kVA) .75 Output Watt Capacity (Watts) 675 Output Capacity Details ON LINE MODE: Maximum output capacity is reduced to 608 watts at 100V nominal FREQUENCY CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120/115/110V: 472 watts / 100V: 425 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits) Power Factor 0.9 Crest Factor 3:1 Nominal Output Voltage(s) Supported 100V 110V 115V 120V 127V Nominal Voltage Details 120V factory-default nominal voltage Frequency Compatibility 50 / 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup Output matches input frequency when +/-5Hz of nominal Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz. Output Voltage Regulation (Line Mode) +/- 2% Output Voltage Regulation (Economy Line Mode) +/- 10% Output Voltage Regulation (Battery Mode) +/- 3% Output Receptacles (6) 5-15R Load Management Receptacles Two switchable single-outlet 5-15R l |
INPUT Rated input current (Maximum Load) 8A Nominal Input Voltage(s) Supported 100V AC 110V AC 115V AC 120V AC 127V AC Nominal Input Voltage Description 120V factory default UPS Input Connection Type 5-15P Input Circuit Breakers 15A UPS Input Cord Length (ft.) 10 UPS Input Cord Length (m) 3.0 Recommended Electrical Service 15A 120V Input Phase Single-Phase |