Tripp-Lite UPS SU750RTXLCD2U SmartOnline 750VA 15A 120V 675W 2U Rack/Tower Retail
Status: Available
SKU: 203445
Vendor: Tripp Lite
MPN: SU750RTXLCD2U
UPC: 037332168276
EAN:
750VA / .75kVA / 675W on-line double-conversion 2U rack / tower UPS
100/110/120/127V 50/60Hz output; High efficiency economy mode option
Interactive LCD with 9 selectable screens of UPS and site power data
Expandable runtime, Hot-swap batteries, 12.5 in / 31.8 cm depth
USB, RS232 & EPO ports, plus support for network card options
2 independently switched load banks
NEMA 5-15P input; 6 NEMA 5-15R outlets
OUTPUT
Output Volt Amp Capacity (VA)
750
Output kVA Capacity (kVA)
.75
Output Watt Capacity (Watts)
675
Output Capacity Details
ON LINE MODE: Maximum output capacity is reduced to 608 watts at 100V nominal FREQUENCY CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120/115/110V: 472 watts / 100V: 425 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
Power Factor
0.9
Crest Factor
3:1
Nominal Output Voltage(s) Supported
100V 110V 115V 120V 127V
Nominal Voltage Details
120V factory-default nominal voltage
Frequency Compatibility
50 / 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details
ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup Output matches input frequency when +/-5Hz of nominal Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz.
Output Voltage Regulation (Line Mode)
+/- 2%
Output Voltage Regulation (Economy Line Mode)
+/- 10%
Output Voltage Regulation (Battery Mode)
+/- 3%
Output Receptacles
(6) 5-15R
Load Management Receptacles
Two switchable single-outlet 5-15R l
INPUT
Rated input current (Maximum Load)
8A
Nominal Input Voltage(s) Supported
100V AC 110V AC 115V AC 120V AC 127V AC
Nominal Input Voltage Description
120V factory default
UPS Input Connection Type
5-15P
Input Circuit Breakers
15A
UPS Input Cord Length (ft.)
10
UPS Input Cord Length (m)
3.0
Recommended Electrical Service
15A 120V
Input Phase
Single-Phase