Tripp Lite UPS SU2200XLCD SmartOnline 2.2kVA 1-Phase Double-Conversion 1800W Retail
Status: Available
SKU: 136789
Vendor: Tripp Lite
MPN: SU2200XLCD
UPC: 037332174659
EAN:
SmartOnline 2.2kVA On-Line Double-Conversion UPS, Tower, Interactive LCD display, 100/110/120/127V NEMA 5-15/20R L5-20R outlets

2200VA / 2.2kVA / 1800 watt on-line double-conversion tower UPS

100/110/120/127V 50/60Hz output, 97% efficiency economy mode option

Interactive LCD with 10 selectable screens of UPS and site power data

Expandable runtime, Hot-swappable batteries

USB, RS232 EPO ports, SNMPWEBCARD option

2 independently switched load banks

NEMA 5-20P input 6 5-15/20R 1 L5-20R outlets
OUTPUT
Output Volt Amp Capacity (VA)
2200
Output kVA capacity (kVA)
2.2
Output Watt Capacity (watts)
1800
Output kW capacity
1.8
Output power factor
0.82
Output Capacity Details
ON LINE MODE: Maximum output capacity ratings are reduced for some nominal voltage settings (127/120V 1800 watts, 115V 1620 watts, 110V 1530 watts, 100V 1440 watts). FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1260 watts, 115V 1134 watts, 110V 1071 watts, 100V 1008 watts).
Crest Factor
3:1
Nominal Output Voltage(s) Supported
100V 110V 120V 127V
Nominal Voltage details
120V default
Frequency compatibility
50 / 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency compatibility details
ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup Output matches input frequency when +/-5Hz of nominal Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.
Output voltage regulation (line mode)
+/- 2%
Output voltage regulation (Economy line mode)
+/- 10%
Output voltage regulation (Battery mode)
+/- 3%
Built-in UPS output receptacles
6 5-15/20R outlet(s) 1 L5-20R outlet(s)
Built-in controllable switched load banks
Two switchable three-outlet load banks
Output AC waveform (AC mode)
Pure Sine wave
Output AC waveform
Pure Sine wave
INPUT
Rated input current (at maximum load)
16A
Nominal Input Voltage(s) Supported
100V AC 110V AC 120V AC 127V AC
Nominal input voltage description
120V factory default
UPS input connection type
5-20P
Input circuit breaker
30A
UPS Input cord length (ft.)
10
UPS Input cord length (m)
3
Recommended Electrical Service
15A 120V