Status: | Available |
SKU: | 136788 |
Vendor: | Tripp Lite |
MPN: | SU1500XLCD |
UPC: | 037332174642 |
EAN: | |
1500VA / 1.5kVA / 1350 watt on-line double-conversion tower UPS 100/110/120/127V 50/60Hz output, 97% efficiency economy mode option Interactive LCD with 10 selectable screens of UPS and site power data USB, RS232 EPO ports, SNMPWEBCARD option Expandable runtime, Hot-swappable batteries 2 independently switchable load banks NEMA 5-15P input 6 5-15R outlets |
|
OUTPUT Output Volt Amp Capacity (VA) 1500 Output kVA capacity (kVA) 1.5 Output Watt Capacity (watts) 1350 Output kW capacity 1.35 Output power factor 0.9 Output Capacity Details ON LINE MODE: Maximum output capacity ratings are reduced for some nominal voltage settings (127/120V 1350 watts, 115V 1215 watts, 110V 1148 watts and 100V 1080 watts). FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 945 watts, 115V 851 watts, 110V 804 watts, 100V 756 watts). Crest Factor 3:1 Nominal Output Voltage(s) Supported 100V 110V 120V 127V Nominal Voltage details 120V default Frequency compatibility 50 / 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency compatibility details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup Output matches input frequency when +/-5Hz of nominal Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal. Output voltage regulation (line mode) +/- 2% Output voltage regulation (Economy line mode) +/- 10% Output voltage regulation (Battery mode) +/- 3% Built-in UPS output receptacles 6 5-15R outlet(s) Built-in controllable switched load banks Two switchable three-outlet load banks Output AC waveform (AC mode) Pure Sine wave Output AC waveform (battery mode) |
INPUT Rated input current (at maximum load) 12A Nominal Input Voltage(s) Supported 100V AC 110V AC 120V AC 127V AC Nominal input voltage description 120V factory default UPS input connection type 5-15P Input circuit breaker 15A UPS Input cord length (ft.) 10 UPS Input cord length (m) 3 Recommended Electrical Service 15A 120V |